Water (10%), solvent (60%) and gas (30%) phases. Solvent and gas mixtures specified in the relevant standards. Samples typically maintained in the solvent phase.
Gas phase pressurised to 60bar at ambient, sealed and then the vessel taken to test temperature. This ensures the same reactive volume of H2S for each test. Pressure and temperature are monitored throughout
Volume, hardness and tensile property changes.
Testing of samples at periodic time intervals, at a minimum of three temperatures,, allows for lifetime predictions using the Arrhenius approach as specified in NORSOK M-710 and ISO 23936. All test temperatures above those of the operating environment.